Tankless Water Heater Sizing: GPM Math for Real Households

How to size a tankless by simultaneous-fixture demand and U.S. groundwater temperature — without overpaying for capacity.

Tankless units are rated by gallons per minute (GPM) at a given temperature rise. In the United States, incoming groundwater runs 45–55°F in winter. To deliver 110°F at the tap, you need a 55–65°F rise — significantly more than the 35–45°F rise manufacturers use in marketing GPM numbers.

Real GPM at winter inlet

A unit advertised at "9.8 GPM" might deliver only 6.5 GPM at a 60°F rise. Always derate by 30–35% for winter performance, then size to your simultaneous-fixture demand.

Simultaneous demand by fixture

  • Shower (low-flow): 1.8 GPM
  • Shower (older head): 2.5 GPM
  • Kitchen faucet: 1.5 GPM
  • Bathroom faucet: 1.2 GPM
  • Dishwasher: 1.0 GPM
  • Washing machine (hot fill): 2.0 GPM

Sizing rules

Pick the two worst-case simultaneous fixtures (typically two showers, or shower + kitchen). Add their GPM. Match a unit whose winter-derated GPM at 60°F rise meets that total. For most 2–3 bath homes, that lands on a 180–199k BTU condensing unit.

Where contractors oversize

Quotes for "199k BTU" units in 1-bath condos are common. The unit will run fine, but you paid $800–$1,200 extra and your gas meter may not support it. Right-sizing also keeps the unit firing in its efficient modulation range.